Search results for "Ophthalmic Procedures"
showing 8 items of 8 documents
Internal limiting membrane peeling versus no peeling during primary vitrectomy for rhegmatogenous retinal detachment: A systematic review and meta-an…
2018
Background Internal limiting membrane (ILM) peeling during primary vitrectomy for rhegmatogenous retinal detachment (RRD) prevents the formation of postoperative macular epiretinal membrane (ERM). However, studies that compared vitrectomy with and without ILM peeling for RRD, have reported controversial outcomes. Objective To assess the efficacy of ILM peeling versus non-ILM peeling during vitrectomy for RRD by a systematic review and meta-analysis of published studies. Methods PubMed, Medline, Web of Science, Embase databases, and the Cochrane Library were searched up to April 2018 to identify studies that compared primary vitrectomy with and without ILM peeling for RRD with at least six m…
Primary vitrectomy for degenerative and tractional lamellar macular holes: A systematic review and meta-analysis
2021
Purpose To assess the efficacy of vitrectomy in degenerative and tractional lamellar macular holes (LMHs) by meta-analysis of published studies. Methods PubMed, Medline and Embase databases were searched up to May 2020. Included cohorts were divided into three groups: degenerative LMH group, lamellar hole associated epiretinal proliferation (LHEP) group and tractional LMH group. LHEP is likely to be associated with degenerative LMHs, but less commonly could be associated with mixed LMHs. To reduce risk of possible misclassification bias, eyes with LHEP which could not have been precisely classified by the authors, were included into the LHEP group. The primary outcome was to investigate th…
Perioperative pupil size in low-energy femtosecond laser-assisted cataract surgery
2020
Purpose To assess potential changes in pupil size during femtosecond laser-assisted cataract surgery (FLACS) using a low-energy laser system. Methods The pupil sizes of eyes undergoing FLACS were measured using the Ziemer LDV Z8 by extracting images from the laser software after each of the following steps: application of suction, lens fragmentation, and capsulotomy. Furthermore, the pupil diameters were measured based on preoperative surgical microscope images and after releasing the suction. Paired t-test and the two one-sided tests (TOST) procedure were used for statistical analyses. The horizontal and vertical pupil diameters were compared in each of the steps with preoperative values.…
Efficacy and safety of preoperative IOP reduction using a preservative-free fixed combination of dorzolamide/timolol eye drops versus oral acetazolam…
2017
Introduction To demonstrate that preoperative treatment for 28 days with topical dorzolamide/timolol is non-inferior (Δ = 4 mm Hg) to oral acetazolamide and topical dexamethasone (standard therapy) in terms of intraocular pressure (IOP) reduction 3 and 6 months after trabeculectomy in glaucoma patients. Materials and methods Sixty-two eyes undergoing trabeculectomy with mitomycin C were included in this monocentric prospective randomized controlled study. IOP change between baseline and 3 months post-op was defined as the primary efficacy variable. Secondary efficacy variables included the number of 5-fluorouracil (5-FU) injections, needlings, suture lyses, preoperative IOP change, hyperten…
A New Method for Revision of Encapsulated Blebs after Trabeculectomy: Combination of Standard Bleb Needling with Transconjunctival Scleral Flap Sutur…
2016
Purpose A simple needling procedure is the standard method for restoring the function of an encapsulated bleb after trabeculectomy. However, postoperative hypotony represents a possible hazard. This study describes a new surgical approach for treating encapsulated blebs with reduced risk of early postoperative hypotony: bleb needling combined with transconjunctival sutures tightening the scleral flap directly. Methods The study included two groups of 23 patients with failing bleb following trabeculectomy: “Group 1” underwent simple needling revision of the filtering bleb and served as a control group, while “Group 2” received needling revision with additional transconjunctival scleral flap …
Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale.
2016
Purpose To assess nuclear and cortical opacities through the objective analysis of Scheimpflug images, and to check the correlation with the Lens Opacity Classification System III (LOCS III). Methods Nuclear and cortical opacities were graded according to the LOCS III rules after pupil dilation. The maximum and average pixel intensity values along an elliptical mask within the lens nucleus were taken to analyse nuclear cataracts. A new metric based on the percentage of opaque pixels within a region of interest was used to analyse cortical cataracts. The percentage of opaque pixels was also calculated for half, third and quarter areas from the region of interest’s periphery. Results The maxi…
Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry.
2016
AIMS The tonographic effect is a phenomenon of intraocular pressure (IOP) reduction following repeated tonometry. This study examines whether the tonographic effect occurs following IOP measurement performed with Ocular Response Analyzer (ORA). METHODS Both eyes of 31 glaucoma patients and 35 healthy controls underwent nine IOP-measurements performed with GAT and ORA. The number of GAT and ORA measurements performed on each eye differed depending on the randomly allocated investigation scheme. Central corneal thickness (CCT), anterior chamber volume (ACV) and anterior chamber depth (ACD) were assessed with Pentacam before and after the repeated GAT/ORA measurements. RESULTS There was no sta…
Fractal-structured multifocal intraocular lens
2017
[EN] In this work, we present a new concept of IOL design inspired by the demonstrated properties of reduced chromatic aberration and extended depth of focus of Fractal zone plates. A detailed description of a proof of concept IOL is provided. The result was numerically characterized, and fabricated by lathe turning. The prototype was tested in vitro using dedicated optical system and software. The theoretical Point Spread Function along the optical axis, computed for several wavelengths, showed that for each wavelength, the IOL produces two main foci surrounded by numerous secondary foci that partially overlap each other for different wavelengths. The result is that both, the near focus an…